RM direct reading flowmeters

The direct reading flowmeters type RM are flow measuring devices suitable for small flows of liquid and gaseous fluids. The measure cone is got directly from the acrylic body of the flowmeter. They can have three different constructions: with square connections (with or without needle valve), with lateral or frontal connections with needle valve. Their working principle is very simple and they are particularly suitable for gas-therapy, purge, analysis and level measurements.

Other features, besides the ones already mentioned, are:

  • connections and needle valve made of brass or stainless steel AISI 316;
  • bodies with different sizes depending on use to be made at request.

Technical Details (below)

Execution 1: With square connections
Execution 2: With lateral connections
Execution 3: With frontal connections

read more

Tech Info

FEATURES

Accuracy

± 10% V.F.S.

Working max. pressure

10 bar

Working max. temperature
with standard gaskets

50° C.

Connections made of chrome-plated brass or of AISI 316

ACCESSORIES

Differential pressure regulator

Connections for tubing

Outlet adjusting needle valve (only for construction type "1")

TYPE A B Q WATER L/h Q AIR NL/h
1013 mbar
THREAD C D CONSTR.

MIN

MAX

MIN

MAX

RM/95

95

26

5

50

60

900

G1/4” G3/8”

65

1

RM/100

100

26

5

50

60

1200

G1/4” G3/8”

70

1

RM/105

105

30

5

80

60

1800

G1/4” G3/8”

75

1

RM/120

120

30

6

120

60

3000

G1/4” G3/8”

90

1-2-3

RM/145

145

30

10

120

90

6000

G1/4” G3/8”

115

1-2-3

RM/185

185

30

50

200

300

6000

G1/4” G3/8”

155

1

RM/V

120

30

-

-

1

60

G1/4” G3/8”

90

1

Image
RM | flow-meter™

Download Area

Download here below the product sheet of this product. You can find any other information and document here.